Table of Contents
- 1 Where does expansion vessel go on heating system?
- 2 Where should the expansion tank be installed?
- 3 What pipe does an expansion vessel go on?
- 4 Where is the expansion vessel on a combi boiler?
- 5 What is an expansion vessel in a domestic hot water system?
- 6 Why does the water expand in the expansion pipe?
- 7 Can a cold feed pipe be used as an expansion pipe?
Where does expansion vessel go on heating system?
The Expansion Vessel must be fitted to the Return Side of the Central Heating System and in such a way that there can at no time be an obstruction between the vessel and the system.
Where should the expansion tank be installed?
An expansion tank is generally installed directly above the water heater by means of a tee-fitting installed in the cold water delivery pipe. The expansion tank is usually installed horizontally, though it is acceptable to install it vertically if it is necessary because of space limitations.
Does the expansion tank go on the hot or cold side?
Although expansion tanks can be installed on the hot side, we strongly recommend they be installed on the cold line, downstream of the shutoff valve.
Where does the expansion vessel go on an unvented cylinder?
What Is an Expansion Vessel? If you’ve noticed that there’s a smaller tank attached to your water cylinder, this is the expansion vessel. It may be mounted to the top of the cylinder, or it could be attached in some other location. With some models, it is actually within the casing of the water heater.
What pipe does an expansion vessel go on?
The new pipe work needs to connect the return pipe from the boiler to the Expansion vessel. Here we have used 15mm copper pipe (plastic pipe should never be used close to a boiler) and compression fittings. The connector that fits on top of the expansion vessel is a 3/4 inch tap connector.
Where is the expansion vessel on a combi boiler?
Expansion vessels, also known as expansion tanks, keep the pressure in a combi boiler stable while water heats and cools. They are typically located inside the boiler casing. The typical pressure a boiler system should be set to is 1 bar.
How close should expansion tank be to water heater?
18 inches
The items which should be installed in sequence in the cold water line are (1) the EXPANSION TANK must be installed at least 18 inches away from the cold water inlet fitting on the water heater, (2) the PRESSURE GAUGE, and (3) the PRESSURE REDUCING VALVE, if required, see Figure 1. 3.
Why is the expansion tank on the cold side?
One expansion tank manufacturer states: “We recommend the cold water side installation because the tank is not insulated. When the expanded volume enters the tank, it will cool down. With the tank on the cold water side, this expanded volume will pass through the water heater before going out to the faucets.”
What is an expansion vessel in a domestic hot water system?
Expansion tanks are also known as expansion vessels and are used to protect closed water heating systems and domestic hot water systems from excessive pressure. As the water heats up the pressure can increase by 4.5% so they are a very important part of any sealed system.
Why does the water expand in the expansion pipe?
Because the weight is much lighter in the expansion pipe, the water then expands through the expansion rather than the cold feed. As the water is much heavier in the central heating tank, when getting the supply of water into the central heating system, it then draws the heavier sauce off water supply.
Why is the expansion pipe at 22mm in central heating?
The first reason why the expansion pipe is at 22mm is because, it is more likely not to block up if the rest of the central heating is at 22mm circuit. The second reason that the 22mm pipe is bigger than the cold feed 15mm pipe is because, the flow is not as restricted and easier to let the water expanding to find the expansion vent pipe.
What is an expansion vessel in a central heating system?
This is used in a sealed central heating system to control expansion in the pipes and radiators, because as water is heated it gets bigger in volume by about 4%, and this water has to go somewhere. The expansion vessel is designed to take up the slack and stop the parts of the system bursting.
Can a cold feed pipe be used as an expansion pipe?
If you had a cold feed used also as the expansion pipe, it doesn’t mean that the central heating won’t work, it just means that you are more open to problems, with a combined cold feed & open vent, where the central heating system isn’t pacifically designed for this.