What causes generator over current?
IVR EXCITATION MODULE OVER-EXCITATION PROTECTION This protection strategy, illustrated in Figure 2, provides a continuous excitation current well below the upper limit under normal conditions.
What causes generator over voltage?
There are plenty reason of overvoltage in generator. They are, If the generator engine speed is unstable that means too high, then the voltage increase significantly. If working load is exceed than the generator efficiency, and then the voltage will be unstable.
How many percent is apply in overcurrent protective device maximum?
430.32 specify that overload protection device be sized between 115% to 140% of the motor nameplate current rating.
What is over voltage in generator protection?
Over voltage protection is used to protect the synchronous Generator/transformer/alternator form high voltage. the power system must be isolated when the system voltage high. Seviour overvoltage causes the winding or electrical insulation failure, over fluxing (u/f), transformer’s core saturation etc.
How do you protect a generator from overload?
Stay within the output rating of your generator and turn off all non-essentials, such as multiple televisions, dishwashers and washing machines. This will stop your generator from overloading and also conserve fuel. The holiday lights and video games can wait until power is completely restored.
What is generator differential protection?
1. Generator differential protection (87 G) It is unit type protection, covering the stator winding for phase to phase faults due to breakdown of insulation between stator phase windings. If CTs of identical ratios are used on neutral and line side of generator, an operating current setting of 20% it can be adopted.
What happens if overvoltage?
The overvoltage can cause excessive current to flow as well as creating excessive voltage stresses. In both cases, the electrical insulation system inside the motor or equipment can be degraded reducing life or causing damage.
How do you reduce voltage in a generator?
Adjust the throttle of the generator to increase or decrease RPMs of the machine’s motor. Slowing the RPMs decreases the voltage output; increasing RPMs increases the voltage output.
What is considered over current protection?
ANSWER: Overcurrent protection is protection against excessive currents or current beyond the acceptable current rating of equipment. It generally operates instantly. Magnetic circuit breakers, fuses and overcurrent relays are commonly used to provide overcurrent protection.
What is an over current protection device?
Overcurrent protection devices include circuit breakers and fuses. Overcurrent protection devices are meant to protect against the potentially dangerous effects of overcurrents, such as an overload current or a short-circuit current, which creates a fault current.
How does the overvoltage relay work?
An over-voltage relay operates when the current produced by a load, or device connected to the output of a circuit, exceeds a predetermined value. The relay is calibrated to operate at or over a preset voltage level. When the relay is switched on, one or multiple contacts trip, or open a circuit breaker.
What are the reasons for unbalanced current condition on a generator?
The negative sequence components of these currents cause double frequency currents in the rotor that can lead to overheating and damage.
- Over Voltage.
- Under Voltage.
- Dead Generator Energization Protection.
- Over Frequency.
- Under Frequency.
- Stator Ground Fault.
How to set the overload value of a circuit?
Basically to setting the overload value,we refer to this formula : 1) IB ≤ In ≤ IZ. IB = Anticipated operating current of the circuit. IZ = Current carrying capacity of conductor or cable or Motor. In = Rated current of protective device.
What happens to the CT secondary current when the current increases?
As the current in the system increases, the secondary current of the current transformer is increased proportionally. The secondary current enters the relay current coil. But when the CT becomes saturated, there would not be a further proportional increase of CT secondary current with increased system current.
What are the requirements for feeder circuit overcurrent protection?
The requirements for feeder-circuit overcurrent protection are found in Section 215.3 and are similar to the requirements for branch circuits. As with branch circuits, the general requirement is to size the OCP no less than 125% of the continuous load and 100% of the noncontinuous load.
What is the overload relay size for a 45kW motor?
In what condition I shall used 30mA or/and 100mA (tripping relay). You can set your overload relay at 105A and the Breaker size is 200A. I have a 45kw motor with a FLC of 86 A. It used to take 72A earlier but due to some changes done to process parameters is taking 93A for 10 seconds with a frequency of 2 times a minute.