Calculate Steel quantity in slab as 1% of volume of concrete = 0.01× 7850× 1= 78.50kg:- according to using Thumb Rule Steel quantity required for RCC slab should be 1% of total volume of concrete, here steel density = 7850 kg/m3, so quantity of steel in 1m3 of concrete slab = 0.01× 7850× 1= 78.50kg, so, therefore 78.50 …

What is the cost of making a 400 sq ft RCC roof?

To get a rough idea for the construction cost you can get a hint from this formula, however, in general, it is assumed that to construct an RCC roof slab the approx cost would be Rs 180 to 200-00 per Sq Ft, where the cost for steel, labor, shuttering and material is included.

What is the total cost of a 1500 sq feet RCC roofing?

1602.8 Kg steel, 262.21 Cuft sand, 143.55 bags ( 7177.5 kg) cement and 524 Cuft aggregate is required for roof cast of 1500 square feet rcc slab and total cost of material is about rs 279099.

What is the percentage of steel in RCC?

5) Thumb Rule for Steel in slab is 1% – 1.5% of wet volume of concrete.

How much steel is needed?

Thumb rule for Steel required for RCC slab is 80 kgs/m3, then quantity of steel required for 100 sq ft ( 1.416 m3) rcc slab is equal to = 80 × 1.416 = 113.3 Kgs.

How much steel is RCC slab?

Thumb rule for Steel required for RCC slab is 80 kgs/m3, then quantity of steel required for 100 sq ft ( 0.944 m3) rcc slab is equal to = 80 × 0.944 = 75.5 Kgs. Ans. :- 75.5 Kgs steel quantity are required for 100 sq ft 4 inch thick rcc roof slab.

How is RCC calculated?

Lets take example of RCC Column, where reinforcement required is 2.5% of concrete volume, weight of steel required will be: =196.25 kg….d) Estimation of Reinforced Steel:

  1. For slabs = 1.0 % of concrete volume.
  2. For Beam = 2 % concrete volume.
  3. For column = 2.5 % of concrete volume.
  4. For RCC Roads, 0.6% concrete volume.

How much steel required for 100 sq ft RCC roof slab?

Thumb rule for Steel required for RCC slab is 80 kgs/m3, then quantity of steel required for 100 sq ft ( 0.944 m3) rcc slab is equal to = 80 × 0.944 = 75.5 Kgs. Ans. :- 75.5 Kgs steel quantity are required for 100 sq ft 4 inch thick rcc roof slab.

How many cement bags required for 100 square feet RCC slab?

Number of cement bags are required for 100 sqft 6 inch slab = 11.4 bags. How many cement bags required for 100 square feet 5 inch thick RCC slab? For this calculation we have given following

How much steel required for 1 sq ft area?

How much steel required for 1 sq.feet area:- using M20 grade of concrete in rcc load bearing structure like column, beam, floor and roof slab casting, 1 sq.feet area of house construction, RCC structure require average 3.8kgs of steel.

What is the size of steel rods required for RCC framed structure?

Hence steel rods required will be 80 x 9.34 = 747.2kg Cement can be 3.5 to 5 kg/Sqm of covered area and steel may be taken as 60 to 79 kg/Sqm. It is for preliminary estimate only for RCC framed structure.