How is smoke density measured?
The Smoke Density Chamber is used to measure propensity of building materials to generate smoke when exposed to a heat source. The smoke propensity is quantified by measuring the obscuration of a light beam traveling through the smoke generated within the chamber.
How does density affect smoke?
The experimental result showed that bed density affects the the smoldering velocity, mass loss rate and smoke light transmisivity. At higher bed density smoldering velocity and mass loss rate increases, but the smoke took a longer period time to reach the bed surface.
What is smoke density of cable?
Cable Smoke Density Testing to BSEN 61034 (previously BS EN 50268) is commonly known as the 3 metre cube test. It is designed to determine the volume of smoke generated when cables are burned. Over a period of 40 minutes the cables are burned whilst a beam of white light crosses the chamber.
What is a good smoke developed index?
The ASTM standard E84 defines a standard test method for surface flame spread and smoke density measurements. A smoke-developed index of less than 450 is required by IBC section 803.1 at interior walls and ceilings for all surface materials except trim.
What is smoke number?
Smoke number is the fractional reduction in reflectance by a smoke filter due to the blackening of its surface by soot. Extinction coefficient is the inverse of the path length over which light intensity decreases by the factor of e (2.718).
Is smoke denser than air?
Smoke is heavier than air, but normally floats upwards because it is hot. The tube gives the smoke enough time to cool down, after which it doesn’t rise up, but instead falls to the floor like a waterfall.
What is the unit of smoke density?
A number of methods have been developed that allow the conversion of opacity or smoke number measurements into PM mass units—soot density [mg/m3] or mass fraction [mg/kg] [301] . Being fast and inexpensive, smoke measurements are sometimes used as a substitute for other PM measurement methods.
Is 10810 a temperature index test?
The temperature index is the temperature in ‘C at which theoxygen index of a material becomes 21 (the approximate percentage of oxygen in air) under the conditions of the test. The test apparatus is same as recommended for oxygen index test in IS 10810 (Part 58) with appropriate heating system.
What IEC 61034?
This part of IEC 61034 provides details of the test apparatus to be used for measuring smoke emission when electric or optical fibre cables are burnt under defined conditions, for example, a few cables burnt horizontally.
What is class 3 flame rating?
What is a Class C or Class 3 fire rating? A Class C or Class 3 fire rating has a flame spread rating between 76 and 200. This rating incorporates building materials like plywood, fiberboard, and hardboard siding panels. It also includes any of the faster burning whole woods.
What is Class A flame spread rating?
Class A fire retardants have a flame spread rating of between zero and 25. These materials are effective against severe fire exposure. Class B fire retardants have a flame spread rating of between 26 and 75. These materials are effective against moderate fire exposure.
What is smoke meter?
Smoke meters, also referred to as opacity meters, detect and measure the amount of light blocked in smoke emitted by diesel engines from cars, trucks, ships, buses, motorcycles, locomotives and large stacks from industrial operations.